    If I run this indicator:

    on CADJPY Mini (and many other MINI contracts), with TF’s 1-hour, 2-hour and 4-hour it reports the attached error (pic x2), while if I run it in TF’s lower than 1-hour or I use 59 minutes, 119 minuts, 239 minutes (pic x1), it works finely.

    If I replace UNDER with OVER everything works on all instruments and TF’s I tested!

    Any suggestion?

    #84298

    I have no suggestion, it looks like a weird hided bug! 😉 I will report it to ITF.

    1 user thanked author for this post.
    #85931

    This bug is still no present. Since your post, one of the recent new builds of the platform has fixed it.

    #85932

    Great news Nicolas!

    Thanks.